        1. Data Center Map

          EhostIDC


          » Index » South Korea » Seoul » EhostIDC

          EhostIDC is located in the area Seoul, South Korea (Republic of Korea), and the colocation data center is carrier neutral. The data center was last updated on 08-10-2019.


          Address:
          EhostIDC
          Gasan Digital 1-ro 189
          37371 Seoul
          South Korea

          » Request quote
          » Visit website

          Click here to find other data centers
          owned and operated by EhostIDC.


          Profile
          Gallery
          Tenants
          Connectivity
          Request quote
          Office space
          Rack Cabinets
          Dedicated Servers
          Suites
          Footprints
          Virtual Servers
          Cages
          Hosting of individual servers
          Remote Hands

          Profile


          Ehost Internet Data Center in LG CNS Building:

          Carrier Neutral

          1. Building outline

          - Construction commenced : 2009
          - Scale : 1 underground floor, 13 above ground floors
          - Site area : 14,946 m2
          - Floor area : 75,041 m2
          - Machine Room area : 12,060 m2

          2. Characteristics

          - Earthquake resistant design : up to 7.0 on the Richter scale
          - Exclusive power supply for both main and reserve power, redundant backup power system
          - Modular/tailored facility environment and green IT solution application

          3. Earthquake facilities

          - Resistant to up to 0.2g of seismic acceleration : Richter scale 7.0

          4. Flooding (tsunamis, floods)

          - Located in a safe zone away from risk inducing structures (Digital City)
          - Located in a flood safe zone (7m above water level)

          5. Power supply method

          - Redundant supply line from Korea Electric Power Corporation
          - Direct connection to the substation forlarge-scale power distribution (exclusive line)
          - Physical separation of incoming lines and pipes
          - Redundant ALTS and MOF high voltage lines
          - Backup high voltage transformers installed
          - Transformer and UPS N+1 methodology

          6. UPS and emergency power generation

          - Redundant exclusive UPS and physically redundant lines
          - Emergency power generator

          7. Cooling systems

          - Main supply : Cooling tower
          - Backup supply : Emergency distributed cooling source in 8 areas for a distributed vertical conduit system
          - Redundant coolant circulation pump and coolant supply conduits
          - Efficient management of the fan inverter control

          8. Isothermal-humidity system

          - Some of the thermo-hygrostats installed in the computer rooms are designed to admit outdoor air during winter, reducing power consumption for cooling and realizing a green data center.
          - Format : Water-cooled
          - Humidification : Separate humidifiers
          - Backup thermo-hygrostats

          9. Central air

          - Cool and hot zones are separately designated, and separate partitions are installed in cool zones to block flow of cool air. This centralized cooling design promotes power saving.
          - Servers separated for each customer(separate cool & hot zones).
          - Grill vents are arranged in cool zones for air conditioning.
          - Separate partitions are installed for containment of cool airflow.
          - Temperature sensors are installed in cool zones for cooling facilities.

          10. Building security systems

          - Bulletproof film on all first floor outside windows
          - Glass damage sensors
          - Fire detection systems (state of the art CCTV)
          - Bollards (posts) installed to prevent unauthorized vehicle entry

          11 Entry/exit control system

          - Lobby entry/exit control
          - Constant security staff presence and speed gate
          - Lockers to store valuables
          - Entry/exit control for the computer room : Interlocking Door (primary biometric recognition system, secondary weight sensor)
          - Integrated security office operations

          12. Vehicle control system

          - Control of incoming cars through security staff
          - Entry/exit control through RF Tags
          - Roadblocks (control of cars entering throughthe exits)
          - Operation of elevators exclusively for vehicle drivers


          EhostIDC Pricing/Quotes


          If you are interested in receiving a quote for EhostIDC, please try our free quote service.

          Copyright © Data Center Map - Sitemap
          Your guide to colocation data centers, managed hosting, cloud servers etc.