          Cogent Charlotte


          » Index » USA » North Carolina » Charlotte » Cogent Charlotte

          Cogent Charlotte is located in the area Charlotte, USA (America), and the colocation data center is carrier neutral. The data center was last updated on 23-12-2019.


          Address:
          Cogent Communications, Inc.
          701 East Trade Street
          28202 Charlotte
          North Carolina, USA

          » Request quote
          » Visit website

          Click here to find other data centers
          owned and operated by Cogent Communications, Inc..


          Profile
          Tenants
          Connectivity
          Request quote
          Office space
          Rack Cabinets
          Dedicated Servers
          Suites
          Footprints
          Virtual Servers
          Cages
          Hosting of individual servers
          Remote Hands

          Profile


          On-Net Products
          . IP Transit
          . Ethernet Transport Services

          Standard Rack Configuration
          . 42U Cabinets (Type: APC AR3100)
          . Power extra (1) 110v/20 amp or (2) 110v/20A is standard

          Facilities
          . 480v 3-phase utility feed - 1,200 amps
          . 2,989 square feet of non raised floor data center space
          . WIFI Available

          Security
          . C*CURE Software House Card Reader Access Control System
          . Building system access badge required for entry at all times building doors locked down 24/7/365
          . (4) IP cameras in use with recording and 24/7/365 monitoring capabilities to the Cogent NOC (1) at main entrance into facility

          UPS Systems
          . (1) UPS Unit - 250 kVA
          . Model: Schneider Electric Galaxy VM
          . (1) Modular Battery Cabinet

          Generator Systems
          . 600kW Caterpillar Diesel Generator
          . 600 gallon diesel fuel storage tank

          Electrical
          . Automatic Transfer Switch (1,200 amps) - RussElectric
          . (1) Schneider Electric "InfraStruxure" PDU - 150KVA

          Fire Systems
          . Fire suppression and detection system consists of heat detectors, smoke heads and a preaction sprinkler system
          . 24/7/365 Monitored

          HVAC
          . (6) Liebert 20-ton HVAC units in Data Center Rooms
          . (1) Liebert 10-ton HVAC Unit in the Electrical Room
          . Rooftop mounted condenser units

          For informational purposes only. Cogent does not guarantee the information set forth above and it may be changed without notice.